Filter Results By:

Products

Applications

Manufacturers

Showing results: 46 - 60 of 277 items found.

  • 8-Channel, 10 MHz Precision ReferenceWith Sine and Logic Outputs

    ITS-6200 - Innovative Technical Systems

    The ITS-6200 is a versatile 10 MHz laboratory frequency reference useful for synchronizing test instruments to a common standard. Eight outputs are provided, each which can be configured independently as sinewave or logic level square-wave signals. Additionally, CMOS logic levels can be set for 5V, 3.3V, or 2.5V logic family compatibility. A 10 MHz reference input is provided to phase lock the ITS-6200 to an external reference, such as a GPS or Rubidium standard, or cascade multiple ITS-6200 units for additional outputs. The low phase noise and high stability OCXO within the ITS-6200 is suitable for the most demanding applications, whether free-running or phase locked. The compact size and low power consumption makes the instrument highly portable and suitable for AC-powered operation in the lab or battery operation in mobile or field applications.

  • Hydrogen Frequency & Time Standard

    CH1-1035 - VREMYA-CH JS Company

    Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.

  • Reference Magnets

    Series MT - Wuntronic GmbH

    The reasonably priced WUNTRONIC standard reference magnets offer the possibility in a simple way of being able to calibrate or to check magnet measuring instruments like Gauss Meter/Tesla Meter with the respectively accompanying probes in a defined magnetic field.

  • MTB Calibration Adapter

    2450-CAL-30 - The Eastern Specialty Company

    The MTB Calibration Adapter (Catalog No. 2450-CAL-30)is a socket adapter that’s designed to bring phase A, B, and C current and potentials of a TESCO Multi-Position Test Board to an external RD-30 reference standard for calibration of the Test Board.

  • Power Meters and Calibration Cells

    Sciencetech, Inc.

    The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.

  • Calibration Services

    Koehler Instrument Company, Inc.

    Koehler offers a growing variety of ISO 17025 certified petroleum testing materials for your calibration and test method validation requirements. Our Technical Service Department provides calibration services conducted with traceable reference materials and standards.

  • GPS Frequency Reference

    E8000 - Quartzlock (UK) Ltd.

    The Quartzlock E8000 GPS Frequency Reference is a breakthrough in exceptionally low cost, traceable, 1-U rack mount, calibration-free, off-air frequency & time standards. These very low cost references maintain the high frequency & time accuracy required for demanding applications. Ultra low noise option are available.

  • Impedance Standards and Calibrators

    MEATEST, s.r.o.

    Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.

  • Advanced Mezzanine Card (AMC) Module

    AMC SyncClock32 - Brandywine Communications

    The AMC-SyncClock32 from Brandywine Communications is an Advanced Mezzanine Card (AMC) module. Precision time is provided to the host computer with zero latency. The onboard microprocessor automatically synchronizes the clock to reference signal inputs. The reference signal inputs handled by the AMC in its standard configuration are IRIG’s A, B/IEEE1344, and NASA 36. Alternatively, the clock in the AMC can be set using commands from host computer and free run using its on-board oscillator as the time base.

  • Phase Locked Oscillators

    ERAVANT

    Phase locked oscillators (PLO) utilize state-of-the-art planar circuits, three-terminal devices and dielectric resonator technology to generate high-quality microwave signals at lower frequencies. Frequency multipliers, amplifiers and filters are used to extend the low frequencies for higher frequency requirements. The standard offering covers the frequency range of 2 to 110 GHz and provides both internal and external reference options. The frequency stability and phase noise are dependent on the oscillator reference type.

  • PD Coupler

    Techimp HQ S.r.L

    Techimp Capacitive PD Couplers offer both the PD and sync signals references, allowing a thorough investigation of the signal originating inside the asset they are connected to.Techimp Couplers are individually tested according to the following international standards: IEC60358; IEC60694; IEC60270.

  • WinSock Trace / Debug Utilities

    SocktSpy - WinTECH Software Design

    The Socket Spy programs are Trace/Debug utilities used for monitoring WINSOCK API references between an application and the Windows Sockets Dynamic Link Library. Socket Spy/16 operates under Windows 3.1 and is fully compatible with the WinSock Ver 1.1 standard.

  • VME Analog Output Module

    DP-VME-2115 - Data Patterns Pvt. Ltd.

    DP-VME-2115 is an industrial standard 24 channel D/A (Digital to Analog) board. It incorporates most of the features which are demanded in industrial applications. Each Digital to Analog Converter (DAC) is provided with a separate reference voltage selection either from internally generated reference or from the external input. This external input reference signal is passed into the protection circuits before it is fed to any active components. The input protection circuit is designed for ± 25Vp-p input ranges. The DAC output may be unipolar or bipolar and the output is jumper selectable, which is routed to the VME P2 connector, with short circuit protection of upto 30mA.

  • Portable Meter Test Kit

    UTEC 430 - Radian Research, Inc.

    The UTEC 430 is the first Portable Meter Test Kit to support both the Radian Dytronic (RD) and the installed base of Radian Metronic (RM) reference standards. The ability to support both reference standards makes the 430 the ideal budgetary solution for traditional on-site meter testing using Phantom Load current sourcing. Do not let its compactness fool you, the UTEC 430 has three 30 Amp current output elements for performing single-phase or three-phase meter testing. When each element is combined using the optional open link cable harness, the UTEC 430 can source up to 90 Amps.

  • 3207a GPS/GNS Frequency and Time Reference

    GlobalTyme2 - Precise Time and Frequency, Inc.

    The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.

Get Help